摘要:核電站模擬量顯示精度是對模擬量點在操作員站上顯示的數據總位數和小數位數的要求,其準確性直接影響操作員對于核電站運行工況的判斷。在核電站DCS系統中存在近萬個模擬量點需要在操作員站上進行顯示,每個點的顯示精度都要依據設定的規則進行測試。目前行業內采用的測試方式為人工逐個測試,測試質量不理想且需要耗費大量的時間。本文通過改變測試方法并開發工具,提出了一種新的模擬量自動化測試方法,以替代傳統人工測試。經實際項目試驗,該方法可以大大提升測試效率和準確性。
關鍵詞:核電DCS;模擬量精度;VBA;自動化測試
Abstract: The accuracy of the analog display quantity in nuclear power plant is the requirement of the total number and fractional number of the data displayed on the operator station, and its accuracy directly affects the operator's judgment on the operation of nuclear power plant. There are nearly ten thousand analog points in the DCS system of nuclear power plant, which need to be displayed on the operator station. The display accuracy of each point needs to be tested according to the set rules. At present, the test method used in the industry is manual test one by one, the test quality is not ideal and it takes a lot of time. By changing the test method and developing the tool, this paper proposes a new automated test method of analog quantity precision to replace the traditional manual test method. Through the actual project test, this method can greatly improve the test efficiency and accuracy.
Key words: Nuclear power plant DCS; Analog accuracy; VBA; Automatictest